How accurate is triaxial RT3TM (RT3) accelerometer for estimating energy expenditure?

Liberato, Selma C. and Bressan, Josefina (2013). How accurate is triaxial RT3TM (RT3) accelerometer for estimating energy expenditure?. Journal of Public Health and Epidemiology,5(2):46-50.

Document type: Journal Article
Attached Files (Some files may be inaccessible until you login with your CDU eSpace credentials)
Name Description MIMEType Size Downloads
Download this reading Liberato_40258.pdf Published version application/pdf 211.04KB 38
Reading the attached file works best in Firefox, Chrome and IE 9 or later.

IRMA ID 11035xPUB49
Title How accurate is triaxial RT3TM (RT3) accelerometer for estimating energy expenditure?
Author Liberato, Selma C.
Bressan, Josefina
Journal Name Journal of Public Health and Epidemiology
Publication Date 2013
Volume Number 5
Issue Number 2
eISSN 2141-2316
Start Page 46
End Page 50
Total Pages 5
Place of Publication Nigeria
Publisher Academic Journals
HERDC Category C1 - Journal Article (DIISR)
Abstract The participants are instructed to remove the RT3 only for sleeping, bathing and swimming activities but some studies have shown the participants remove the accelerometer for longer times. The activities performed while the accelerometer is not being worn and, or energy that was not recorded during this time has never been estimated. This study aimed to assess compliance in using the accelerometer and quantify the energy expenditure (EE) not recorded by the accelerometer during the time it was not worn in free-living young males in a consecutive 4-day period. Eleven male participants 19 to 23 years of age, 54.7 to 85.5 kg with body mass index of 19.1 to 27.6 kg.m-2 completed the study. Resting metabolic rate was measured by indirect calorimetry. Daily EE estimation was on average 23.6% higher using the Bouchard Physical Activity Records than the RT3. Accelerometers were worn for 67 to 98% of waking hours but up to 30% of the EE was not recorded due to the device not being worn by participants mainly during intense physical activity. Recording the physical activity when the accelerometer is not being worn would provide a more precise estimative of the EE.

Keywords Energy expenditure
Accelerometer
Physical activity records
Young men
DOI http://dx.doi.org/10.5897/JPHE11.166   (check subscription with CDU E-Gateway service for CDU Staff and Students  check subscription with CDU E-Gateway in new window)
Additional Notes This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Description for Link Link to CC Attribution 4.0 License
URL https://creativecommons.org/licenses/by/4.0/au/legalcode


© copyright

Every reasonable effort has been made to ensure that permission has been obtained for items included in CDU eSpace. If you believe that your rights have been infringed by this repository, please contact digitisation@cdu.edu.au.

 
Versions
Version Filter Type
Access Statistics: 27 Abstract Views, 38 File Downloads  -  Detailed Statistics
Created: Thu, 07 Aug 2014, 16:56:40 CST